NucMed Boards Prep
IMAGE INTERPRETATION · LUNG V/Q IMAGING

Tc-99m MAA Injection Technique

Lung perfusion scintigraphy — MAA preparation and injection
Lung perfusion scintigraphy — MAA preparation and injection

Public domain · Wikimedia Commons · source file

Question

When preparing and injecting Tc-99m MAA for a lung perfusion scan, which of the following is the correct injection technique to ensure proper MAA distribution?

  1. AInject rapidly as a bolus while the patient is in the upright sitting position
  2. BInject slowly over 3–5 breathing cycles with the patient SUPINE to ensure even MAA distribution throughout both lungs
  3. CMix MAA with blood in the syringe before injection to prevent clumping
  4. DInject into a peripheral vein while the patient performs a Valsalva maneuver
Show the answer and explanation

B. Inject slowly over 3–5 breathing cycles with the patient SUPINE to ensure even MAA distribution throughout both lungs

Tc-99m MAA should be injected SLOWLY (over 3–5 breathing cycles) with the patient in the SUPINE position. Supine injection ensures that blood flow is more evenly distributed between the two lungs (compared to upright, where gravity would direct more flow to the bases). Slow injection prevents transient streaming and ensures the particles distribute proportionally to regional blood flow. Mixing MAA with blood in the syringe is contraindicated as clumping can form larger aggregates. Valsalva maneuver could open a PFO and allow MAA to cross to the systemic circulation.

More lung v/q imaging images

V/Q lung scan — high probability for PEPIOPED II: High-Probability V/Q with High Pretest Probability V/Q lung scan — wedge-shaped peripheral perfusion defectWedge-Shaped Pleural-Based Defect: Pulmonary Embolism Normal lung perfusion scintigraphy — standard 8 projectionsLung Perfusion Projections: Why Lateral Views Matter Ventilation-perfusion (V/Q) lung scan — 58-year-old maleHigh-Probability V/Q Scan: Mismatched Defects Ventilation/perfusion (V/Q) lung scan — multiple projectionsMatched V/Q Defects: Low Probability for PE Lung perfusion scintigraphy — normal study (standard projections)Normal Lung Perfusion Scan and Pulmonary Embolism
← Brain and Kidney MAA Uptake: Right-to-Left ShuntPIOPED II: High-Probability V/Q with High Pretest Probability →

All 130 nuclear medicine images by category →

Practise image interpretation in the app

All 130 images as an interactive quiz, alongside 500 NMTCB and ARRT(N) questions with worked explanations, case studies and timed mock exams. 25 questions are free, no card and no account.

Start free — no card